News

/

Artikel, Latest News, SDG 10, SDG 17, SDG 3, SDG 4, SDG 9

When a Miniplate Breaks but Facial Bones Heal: What Can Go Wrong After Maxillofacial Fracture Surgery?

Thirteen point three percent may sound like a small figure. But for patients who have just undergone surgery to fix a facial bone fracture, that number means roughly one in seven may develop an infection involving the small metal implant placed inside their mouth—a titanium miniplate that is supposed to serve as an anchor for healing.

That is one of the key findings of a systematic review published in F1000Research in March 2025 by a team of researchers from Universitas Gadjah Mada. Led by drg. Bramasto Purbo Sejati, Sp.BMM, from the Department of Oral and Maxillofacial Surgery at FKG UGM, the study synthesized a decade of scientific evidence—from September 2014 to September 2024—on complications arising after miniplate placement for maxillofacial fractures.

Broken Bones, Metal Plates

Maxillofacial fractures are not uncommon. Traffic accidents, falls, and physical violence can fracture the jaw, cheekbones, and even the eye socket within seconds. In many countries, including India and Jordan, traffic accidents are the leading cause. Most patients are men aged 21–30.

To reconnect fractured bone fragments, oral and maxillofacial surgeons use miniplates—small, thin metal plates secured to the bone with screws. Placement takes approximately 25 to 30 minutes and has a high overall success rate. However, being successfully implanted does not always mean being free from complications.

The research team screened 2,289 articles from three major databases: PubMed, Scopus, and the Cochrane Library. After a rigorous selection process based on PRISMA guidelines, 56 studies met the inclusion criteria—28 were interventional studies, including randomized clinical trials, while the remaining 28 were observational studies.

Eight Complications to Watch For

Across the 56 studies, the most frequently reported complications fell into eight categories: infection, wound dehiscence, malocclusion, paresthesia or altered sensation in the skin or mucosa, malunion or non-union, movement of bone segments, hardware failure, and externally palpable miniplates.

Infection ranked first. The overall infection rate was approximately 13.3%, and infection was the leading reason for miniplate removal—accounting for approximately 2.9% of cases in one meta-analysis cited in the paper. One study even found that 17.3% of miniplates used as orthodontic anchorage became infected, influenced by the implant’s proximity to the mucogingival junction and the frequency of patients’ oral hygiene practices.

More concerningly, microbiological identification showed that Staphylococcus aureus was the dominant pathogen at infected sites. This finding highlights the need for routine microbiological evaluation rather than relying solely on standard antibiotic treatment.

“These findings underscore the need for monitoring and mitigating the risk of infection associated with miniplate use.”

— drg. Bramasto Purbo Sejati, Sp.BMM et al., F1000Research, 2025

New Technology, Fewer Complications?

This is where more encouraging news emerges. The studies analyzed indicated that 3D miniplate systems and locking mechanisms were associated with lower complication rates than conventional miniplates.

3D miniplates improve stability and shorten surgical time. A retrospective study involving 336 patients found that only 8.03% experienced minor complications, while major complications occurred in 1.49% of cases. Another study on patient-specific 3D-printed miniplates demonstrated high fixation accuracy and effective bone healing, with no material fractures or plate exposure reported.

However, the researchers caution that the superiority of these newer technologies cannot yet be established statistically. The heterogeneity among studies was too substantial to permit a meta-analysis. Differences in patient demographics, treatment duration, and study design also make direct comparisons challenging.

A Decade of Data, One Step Forward

This study forms part of the doctoral research of drg. Bramasto Purbo Sejati, Sp.BMM, at FKG UGM, with funding support from BPI, LPDP, and the Center for Higher Education Funding and Assessment of the Ministry of Higher Education, Science, and Technology of the Republic of Indonesia. The multidisciplinary research team included Prof. Ahmad Kusumaatmaja from the Department of Physics at UGM, drg. Maria Goreti Widiastuti from the Department of Oral and Maxillofacial Surgery, and drg. Tetiana Haniastuti, Ph.D., from the Department of Oral Biology at FKG UGM, who served as the corresponding author.

The paper underwent open peer review by three reviewers from Universitas Indonesia, Universitas Airlangga, and Ajman University in the United Arab Emirates. All three approved the final version published in March 2025.

For clinicians, these findings are more than a list of potential risks. They provide a roadmap: which miniplate technologies may deliver better outcomes, which complications require the closest monitoring, and why standardized postoperative protocols remain urgently needed. For patients preparing to undergo facial fracture surgery, understanding that the choice of plate may influence the likelihood of complications is information worth knowing before entering the operating room.

DOI Source: https://doi.org/10.12688/f1000research.159017.1

Authors: Nanda Ayu, drg. Achmad Zam Zam Aghasy, M.Kes.