News

/

Artikel, Latest News, SDG 10, SDG 17, SDG 3, SDG 4, SDG 9

Wires, Screws, and a Symmetrical Face Again: An Innovative ZMC Fracture Surgery Technique from Yogyakarta

A 31-year-old man arrived at the emergency department with a visibly asymmetrical face. The right side was swollen, his cheekbone had collapsed inward, and the area around his right eye was bruised like a panda’s eye. He had just fallen from a motorcycle. He was wearing a helmet and remained fully conscious, but his zygomaticomaxillary complex (ZMC) was no longer in its proper position.

This case formed the basis of a recent scientific case report by drg. Bramasto Purbo Sejati, Sp.BMM, a faculty member of the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universitas Gadjah Mada (UGM), together with three oral surgery residents: Muhammad Fuadi, Lina Mariana, and Muhammad Reza Pahlevi. Their case report was published in the international journal Trauma Case Reports (Elsevier, 2026) and presents a more affordable and simpler surgical approach that proved effective for treating ZMC fractures with rotational deformity.

When the Cheekbone Shifts in Three Dimensions

The zygomatic bone is more than just a structure that defines facial contours. It is a key biomechanical support that helps maintain orbital integrity, facial symmetry, and masticatory function. When a fracture occurs, the bone does not simply crack; it can become displaced in three dimensions simultaneously: medial-lateral, superior-inferior, and anterior-posterior.

In this patient, a 3D CT scan revealed a right-sided tetrapod fracture with clear displacement. Based on the Knight and North classification, the fracture was categorized as Group IV, which involves medial rotation. This is one of the more challenging fracture patterns: the bone rotates clockwise while simultaneously moving backward, inward, and downward. Reducing the fracture therefore requires all of these movements to be reversed in a coordinated manner.

In addition to facial asymmetry, the patient experienced paresthesia on the right side of his face and could open his mouth less than two centimeters. Two basic everyday functions—sensation and chewing—were impaired at the same time.

A Modification That Addresses the Limitations of Conventional Techniques

The most common approach to reducing ZMC fractures has traditionally involved an elevator, a lever-like instrument inserted through a small incision to push the bone back into position. The classic Gillies technique, for example, uses an elevator inserted through an incision along the temporal hairline. However, in complex fractures involving medial rotation, an elevator alone may not provide sufficient control to maintain the bone’s position during fixation.

The UGM and Temanggung Regional Hospital team developed a protocol combining a conventional elevator with a modified wire-and-screw traction technique. The procedure was performed under general anesthesia using three surgical approaches: a lateral brow incision to access the lateral orbital wall, a subciliary incision for the infraorbital rim, and a right upper vestibular incision for the zygomaticomaxillary region.

“The combination of an elevator and a modified wire-and-screw technique offers a solution for managing complex ZMC fractures, particularly those involving rotational deformity in medial rotation fractures.”

Here is how the technique works: two temporary cortical screws are placed in the lateral orbital wall, above and below the fracture line. A 0.5-mm stainless-steel wire is then attached between the two screws and twisted. The elevator is first used to reduce the bone laterally and anteriorly. Once the horizontal position has been restored, the wire is twisted to pull the fragment upward, allowing controlled correction of its vertical position. A definitive miniplate is then placed at three fixation points: the lateral orbital wall, infraorbital rim, and zygomaticomaxillary buttress.

The temporary screws and wire are subsequently removed. The three-point fixation system remains securely in place.

A Restored Face—and Lessons That Remain

Twenty-four hours after surgery, a Waters’ view radiograph showed restored facial symmetry. The contour of the cheekbone had returned. Within one week, the paresthesia had improved, mouth opening had increased, and the face appeared symmetrical without complications.

Eighteen months later, the patient reported no complaints. He had no difficulty opening his mouth, and his face remained symmetrical.

The researchers emphasized that the technique is cost-effective and can be implemented using standard surgical instruments already available in most settings, without requiring specialized devices such as Steinmann pins or a Carroll-Girard T-bar, which have been described in previous literature. Compared with elevator-only reduction, the addition of wire-and-screw traction provides safer control of the fracture fragment during plate adaptation. Compared with direct multilevel plate fixation without traction, the technique reduces the need for extensive soft-tissue dissection.

The authors acknowledge that formal biomechanical testing and comparative clinical series are still needed to quantify the technique’s advantages over established methods. But for a patient who arrived with an asymmetrical face and left with his cheekbone restored to its proper position, the technique has already answered the most fundamental question in reconstructive surgery: can the result be seen, felt, and maintained over time? At least in this case, the answer was yes.

DOI Source: 10.1016/j.tcr.2026.101297

Authors: Nanda Ayu, drg. Achmad Zam Zam Aghasy, M.Kes.

Photo: Freepik

Tags

Share News

Related News
27 November 2026

FKG UGM Jalani Asesmen Lapangan, Persiapan Pembukaan Prodi Subspesialis Periodonsia

27 November 2026

Dentistry Award FKG UGM 2026: Merawat Budaya Apresiasi, Menyiapkan Duta Kampus yang Berdampak Nyata

26 November 2026

Ketika Air Liur Mampu Deteksi Kadar Gula Darah